Logix5550 Logic Reference Manual, publication 1756-6.8.5 use a specific Logix5000 controller. CompactLogix Controllers User Manual, publication1769-UM007. ControlLogix System User Manual, publication 1756-UM001. DriveLogix System 5720 User Manual, publication 20D-UM002. DriveLogix5730 Controller for PowerFlex 700S Drives. CompactLogix™ 5370 Controllers User Manual, publication Describes the necessary tasks to install, configure, program, 1769-UM021 and operate a CompactLogix 5370 controller. ControlLogix® System User Manual, publication Describes the necessary tasks to install, configure, program, 1756-UM001 and operate a ControlLogix system. For more information on synchronizing owner-controllers and modules with the CST, see the ControlLogix System User Manual, publication 1756-UM001. Page 65 Common Module Features Fault and Status Reporting between Output Modules and Controllers Chapter 3 ControlLogix digital output modules multicast fault and status data to any owner-controller. For ControlLogix controller information, refer to ControlLogix System User Manual, publication. Slot Status Bits: The Slot Status bits display the connection status for each of the POINT I/O modules that use a rack-optimized connection. – Bit 0 is reserved for the adapter and always reports a value of 1.
Adhere to SIL2 requirements Using ControlLogix in SIL2 Applications Safety Reference Manual publication 1756-RM001 configure and program redundant controller systems ControlLogix Redundancy System User Manual publication 1756-UM523 use a state model for your controller configure equipment phase programs PhaseManager User Manual publication.
Advertising
Rockwell Automation Publication 1734-UM018B-EN-P - October 2013
69
Configure the Adapter for Direct Connection and Rack Optimization in RSLogix 5000 Software Chapter5
Controllogix 5000 Programming Manua…
10. Click OK.
At this point, your POINTBus status LED should be solid green. All the
yellow triangles in your I/O configuration should be gone.
yellow triangles in your I/O configuration should be gone.
11. Click OK to close the dialog.
12. Click File
12. Click File
→
Save to save the project.
Access Module Data
Use the following information to use the I/O adapter data in the ladder logic
program:
program:
•
POINT_IO_Adapter — the name you gave to your EtherNet adapter
Controllogix Instruction Manual
•
# — slot number of POINT I/O module
•
C — configuration, I = input, O = output
Use the controller tags in your ladder program to read input data or write output
data.
data.
•
For ControlLogix controller information, refer to ControlLogix System
User Manual, publication
User Manual, publication
Controllogix System User Manual Publication 1756-um001 Form
.
•
Slot Status Bits: The Slot Status bits display the connection status for each
of the POINT I/O modules that use a rack-optimized connection.
–
of the POINT I/O modules that use a rack-optimized connection.
–
Bit 0 is reserved for the adapter and always reports a value of 1.
–
Each of the other bits (1 to 63) correspond to a POINT I/O module
that you install in the POINT I/O backplane.
that you install in the POINT I/O backplane.
–
In this example, we configured the 1734-AENT adapter for both rack-
optimized and direct connections.
The slot status bits indicate that we installed the module in slot 2 with it
operating correctly:
optimized and direct connections.
The slot status bits indicate that we installed the module in slot 2 with it
operating correctly:
0 = module participating with no errors and
1 = module not participating or connection error (typically, module
removed/missing)
1 = module not participating or connection error (typically, module
removed/missing)